Connected Endpoints¶
AVD supports two different data models for defining connectivity to endpoints:
- “Connected Endpoints” is an endpoint-centric model intended for servers or other use cases where most ports have unique configurations.
- “Network Ports” is a compact and port-centric model intended for configuration of generic port configurations on large ranges of ports.
Both data models share the same underlying implementation and can coexist without conflicts, as long as the same switchports are not defined in both models.
Both data models support variable inheritance from profiles defined under port_profiles
. The profiles can be shared between the models. Any setting defined under the port_profiles
will be inherited from parent_profile
to profile
to adapter
.
Connected Endpoints¶
- The connected endpoints variables define connectivity from the perspective of the endpoints that connect to the fabric.
- Each endpoint can have one or more
adapters
defined, under which the connectedswitches
,switch_ports
andendpoint_ports
must be set. - If port_channel mode is enabled under one “adapter”, all switch_ports connected to that “adapter” will become part of this port-channel.
- The keys used to define
connected_endpoints
are configurable usingconnected_endpoints_keys
. The default keys are:servers
,firewalls
,routers
,load_balancers
andstorage_arrays
.
Network Ports¶
network_ports
is intended to be used withport_profiles
andparent_profiles
to keep the configuration generic and compact, but all features and keys supported underconnected_endpoints.adapters
is also supported directly undernetwork_ports
.- Since all ranges defined under
network_ports
will be expanded to individual port configurations, it is not possible to configure a port-channel with multiple interfaces on the same device. For this special caseconnected_endpoints
should be used.
Variables and Options¶
Connected Endpoints¶
# Dictionary of connected endpoint | Optional
# This should be applied to group_vars or host_vars where endpoints are connecting.
# <connected_endpoints_keys.key> is one of the keys under "connected_endpoints_keys"
# Default keys are "servers", "firewalls", "routers", "load_balancers" and "storage_arrays".
< connected_endpoints_keys.key >:
# Endpoint name, this will be used in the switchport description
< endpoint_1 >:
# rack is used for documentation purposes only
rack: < rack_id >
# A list of adapter(s), group by adapters leveraging the same port-profile.
adapters:
# Example of stand-alone adapter
# Adapter speed - if not specified will be auto.
- speed: < interface_speed | forced interface_speed | auto interface_speed >
# The lists "endpoint_ports", "switch_ports" and "switches" must have the same length.
# Each list item is one switchport.
# Endpoint port(s). Used for description. | Required unless description is set
endpoint_ports: [ < interface_name > ]
# List of switch interfac(es) | Required
switch_ports: [ < switchport_interface > ]
# List of switch(es) | Required
switches: [ < device > ]
# Interface descriptions Description | Optional
description: <description>
# Port-profile name, to inherit configuration.
profile: < port_profile_name >
# Administrative state | Optional - default is true
# setting to false will set port to 'shutdown' in intended configuration
enabled: < true | false >
# Interface mode | Optional
mode: < access | dot1q-tunnel | trunk >
# MTU | Optional
mtu: < mtu >
# L2 MTU - This should only be defined for platforms supporting the "l2 mtu" CLI
l2_mtu: < l2_mtu >
# Native VLAN for a trunk port | Optional
# If setting both native_vlan and native_vlan_tag, native_vlan_tag takes precedence
native_vlan: < native_vlan_number >
native_vlan_tag: < boolean | default -> false >
# Trunk Groups | Required with "enable_trunk_groups: true"
# Trunk Groups are used for limiting vlans on trunk ports to vlans with the same Trunk Group
trunk_groups: [ < trunk_group_1 >, < trunk_group_2 > ]
# Interface vlans | Optional
# If not set, the EOS default is that all vlans are allowed for trunk ports and vlan 1 will be used for access ports
vlans: < vlans as string >
# Spanning Tree
spanning_tree_portfast: < edge | network >
spanning_tree_bpdufilter: < "enabled" | true | "disabled" >
spanning_tree_bpduguard: < "enabled" | true | "disabled" >
# Flow control | Optional
flowcontrol:
received: < "received" | "send" | "on" >
# QOS Profile | Optional
qos_profile: < qos_profile_name >
# PTP Enable | Optional
ptp:
enable: < true | false | default -> false | Required >
# These are the default settings:
# - The global PTP profile parameters will be applied to all connected endpoints where ptp is manually enabled.
# - `ptp role master` is set to ensure control over the PTP topology.
endpoint_role: < follower | bmca | default -> follower >
profile: < aes67 | smpte2059-2 | aes67-r16-2016 | default -> aes67-r16-2016 >
# Configure the downstream interfaces of a respective Link Tracking Group | Optional
# If port_channel is defined in an adapter then port-channel interface is configured to be the downstream
# else all the ethernet-interfaces will be configured as downstream -> to configure single-active EVPN multihomed networks
link_tracking:
enabled: < true | false >
# The default group name is taken from fabric variable of the switch, link_tracking.groups[0].name with default value being "LT_GROUP1".
# Optional if default link_tracking settings are configured on the node.
name: < tracking_group_name >
# 802.1x | Optional
dot1x:
port_control: < "auto" | "force-authorized" | "force-unauthorized" >
port_control_force_authorized_phone: < true | false >
reauthentication: < true | false >
pae:
mode: < "authenticator" >
authentication_failure:
action: < "allow" | "drop" >
allow_vlan: < 1-4094 >
host_mode:
mode: < "multi-host" | "single-host" >
multi_host_authenticated: < true | false >
mac_based_authentication:
enabled: < true | false >
always: < true | false >
host_mode_common: < true | false >
timeout:
idle_host: < 10-65535 >
quiet_period: < 1-65535 >
reauth_period: < 60-4294967295 | server >
reauth_timeout_ignore: < true | false >
tx_period: < 1-65535 >
reauthorization_request_limit: < 1-10 >
# EOS CLI rendered directly on the ethernet interface in the final EOS configuration
raw_eos_cli: |
< multiline eos cli >
# Custom structured config added under ethernet_interfaces.<interface> for eos_cli_config_gen
structured_config: < dictionary >
# Storm control settings applied on port toward the endpoint | Optional
storm_control:
all:
level: < Configure maximum storm-control level >
unit: < percent | pps > | Optional var and is hardware dependent - default is percent)
broadcast:
level: < Configure maximum storm-control level >
unit: < percent | pps > | Optional var and is hardware dependent - default is percent)
multicast:
level: < Configure maximum storm-control level >
unit: < percent | pps > | Optional var and is hardware dependent - default is percent)
unknown_unicast:
level: < Configure maximum storm-control level >
unit: < percent | pps > | Optional var and is hardware dependent - default is percent)
# Monitor Session configuration: use defined switchports as source or destination for monitoring sessions | Optional
monitor_sessions:
- name: < session_name >
role: < source | destination >
source_settings:
direction: < rx | tx | both >
access_group:
type: < ip | ipv6 | mac >
name: < acl_name >
priority: < priority >
# Session settings are defined per session name. Different session_settings with for same session name will be combined/merged
session_settings:
encapsulation_gre_metadata_tx: < true | false >
header_remove_size: < bytes >
access_group:
type: < ip | ipv6 | mac >
name: < acl_name >
rate_limit_per_ingress_chip: < "<int> bps" | "<int> kbps" | "<int> mbps" >
rate_limit_per_egress_chip: < "<int> bps" | "<int> kbps" | "<int> mbps" >
sample: < int >
truncate:
enabled: < true | false >
size: < bytes >
# Settings for all- or single-active EVPN multihoming
ethernet_segment:
# Define a manual short-esi (be careful using this on profiles) or auto-generate an ESI | Required
# Please see the notes under "EVPN A/A ESI dual- and single-attached endpoint scenarios" before setting short_esi: auto
short_esi: < xxxx:xxxx:xxxx | auto >
# Configure this Ethernet Segment for all-active or single-active forwarding | Optional
# If omitted, Port-Channels use the EOS default of all-active
# If omitted, Ethernet interfaces are configured as single-active
redundancy: < all-active | single-active >
# Configure DF algorithm and preferences | Optional
# - auto: Use preference-based algorithm and assign preference based on position of device in the 'switches' list
# e.g. assuming a list of three switches, this would assign a preference of 200 to the first switch, 100 to the 2nd and 0 to the third
# - preference: Set preference for each switch manually using designated_forwarder_preferences key
# - modulus: Use the default modulus-based algorithm
# If omitted, Port-Channels use the EOS default of modulus
# If omitted, Ethernet interfaces default to the 'auto' mechanism detailed above
designated_forwarder_algorithm: < "auto" | "modulus" | "preference" >
# manual preference as described above | Required only for preference algorithm
designated_forwarder_preferences: [ < df_preference_for_each_switch > ]
# Disable preemption for single-active forwarding when auto/manual DF preference is configured | Optional
dont_preempt: < true | false >
# Example of port-channel adapter
- endpoint_ports: [ < interface_name_1 > , < interface_name_2 > ]
switch_ports: [ < switchport_interface_1 >, < switchport_interface_2 > ]
switches: [ < device_1 >, < device_2 > ]
profile: < port_profile_name >
# Port- Channel
port_channel:
# Port-Channel Mode | Required
mode: < "active" | "passive" | "on" >
# Port-Channel ID | Optional
# If no channel_id is specified, an id is generated from the first switch port in the port channel
channel_id : < port_channel_id >
# Port-Channel Description - added after endpoint name in the description | Optional
description: < port_channel_description >
# Port-Channel administrative state | Optional - default is true
# setting to false will set port to 'shutdown' in intended configuration
enabled: < true | false >
# LACP Fallback configuration | Optional
lacp_fallback:
mode: < static > Currently only static mode is supported
timeout: < timeout in seconds > | Optional - default is 90 seconds
# Port-Channel L2 Subinterfaces
# Subinterfaces are only supported on routed port-channels, which means they cannot be configured on MLAG port-channels.
# Setting short_esi: auto generates the short_esi automatically using a hash of configuration elements.
# Please see the notes under "EVPN A/A ESI dual-attached endpoint scenario" before setting short_esi: auto.
subinterfaces:
- number: < subinterface number >
short_esi: < xxxx:xxxx:xxxx | auto > Required for multihomed port-channels with subinterfaces
vlan_id: < VLAN ID to bridge > | Optional - default is subinterface number
# Flexible encapsulation parameters
encapsulation_vlan:
client_dot1q: < client vlan id encapsulation > | Optional - default is subinterface number
# Allocates an automatic short_esi to all ports using this profile
# Please see the notes under "EVPN A/A ESI dual-attached endpoint examples" in this document before setting short_esi: auto.
short_esi: auto
# EOS CLI rendered directly on the port-channel interface in the final EOS configuration
raw_eos_cli: |
< multiline eos cli >
# Custom structured config added under port_channel_interfaces.<interface> for eos_cli_config_gen
structured_config: < dictionary >
# Setting short_esi: auto generates the short_esi automatically using a hash of configuration elements.
# Please see the notes under "EVPN A/A ESI dual-attached endpoint scenario" before setting short_esi: auto.
< endpoint_2 >:
rack: RackC
adapters:
- speed: < interface_speed | forced interface_speed | auto interface_speed >
endpoint_ports: [ < interface_name > ]
switch_ports: [ < switchport_interface > ]
switches: [ < device > ]
profile: < port_profile_name >
- endpoint_ports: [ < interface_name_1 > , < interface_name_2 > ]
switch_ports: [ < switchport_interface_1 >, < switchport_interface_2 > ]
switches: [ < device_1 >, < device_2 > ]
profile: < port_profile_name >
port_channel:
description: < port_channel_description >
mode: '< active | passive | on >'
# Note that short_esi defined here is overridden by short_esi defined under the ethernet_segment section.
# This key will be deprecated in the next major version of AVD.
short_esi: < xxxx:xxxx:xxxx | auto >
ethernet_segment:
short_esi: < xxxx:xxxx:xxxx | auto >
Network Ports¶
The network_ports
data model is intended to be used with port_profiles
and parent_profiles
to keep the configuration generic and compact,
but all features and keys supported under connected_endpoints.adapters
is also supported directly under network_ports
.
Since all ranges defined under network_ports
will be expanded to individual port configurations, it is not possible to configure a
port-channel with multiple interfaces on the same device. For this special case connected_endpoints
should be used.
The expansiont to individual port configurations also lead to inconsistent configurations when used with short_esi: auto
or
designated_forwarder_algorithm: auto
, since those rely on information from multiple switches and interfaces.
# Network Ports | Optional
# All switch_ports ranges are expanded into individual port configurations.
# Switches are matched with regular expressions, which must match the full hostname.
network_ports:
- switches:
- < regex matching the full hostname of one or more switches >
# Switch_ports is a list of ranges using AVD range_expand syntax (see link below).
# Ex Ethernet1-48 or Ethernet2-3/1-48
switch_ports:
- < interface | interface_range >
description: < description to be used on all ports >
# Port-profile name, to inherit configuration.
profile: < port_profile_name >
< any keys supported under connected_endpoints adapters >
For more details and examples of the range_expand
syntax, see the arista.avd.range_expand documentation
Port Profiles¶
# Optional profiles to share common settings for connected_endpoints and/or network_ports
# Keys are the same used under endpoints adapters. Keys defined under endpoints adapters take precedence.
port_profiles:
< port_profile_name >:
# Parent Profile | Optional
# Port_profiles can refer to another port_profile to inherit settings in up to two levels (adapter->profile->parent_profile).
parent_profile: < port_profile_name >
< any keys supported under connected_endpoints adapters >
Connected Endpoints Keys¶
# Define connected endpoints keys, to define grouping of endpoints connecting to the fabric.
# This provides the ability to define various keys of your choice to better organize/group your data.
# This should be defined in top level group_var for the fabric.
# The default values will be overridden if defining this key, so it is recommended to copy the defaults and modify them.
connected_endpoints_keys:
< key_1 >:
type: < type used for documentation >
< key_2 >:
type: < type used for documentation >
# Example
# The below key/pair values are the role defaults.
connected_endpoints_keys:
servers:
type: server
firewalls:
type: firewall
routers:
type: router
load_balancers:
type: load_balancer
storage_arrays:
type: storage_array
Examples¶
Example with profiles¶
# Example
connected_endpoints_keys:
servers:
type: server
firewalls:
type: firewall
routers:
type: router
port_profiles:
VM_Servers:
mode: trunk
vlans: "110-111,120-121,130-131"
spanning_tree_portfast: edge
MGMT:
mode: access
vlans: "110"
DB_Clusters:
mode: trunk
vlans: "140-141"
# servers
servers:
server01:
rack: RackB
adapters:
# Single homed interface from E0 toward DC1-LEAF1A_Eth5
- endpoint_ports: [ E0 ]
switch_ports: [ Ethernet5 ]
switches: [ DC1-LEAF1A ]
profile: MGMT
# MLAG dual-homed connection from E1 to DC1-LEAF2A_Eth10
# from E2 to DC1-LEAF2B_Eth10
- endpoint_ports: [ E1, E2 ]
switch_ports: [ Ethernet10, Ethernet10 ]
switches: [ DC1-LEAF2A, DC1-LEAF2B ]
profile: DB_Clusters
port_channel:
description: PortChanne1
mode: active
server03:
rack: RackC
adapters:
# MLAG dual-homed connection from E0 to DC1-SVC3A_Eth10
# from E1 to DC1-SVC3B_Eth10
- endpoint_ports: [ E0, E1 ]
switch_ports: [ Ethernet10, Ethernet10 ]
switches: [ DC1-SVC3A, DC1-SVC3B ]
profile: VM_Servers
port_channel:
description: PortChanne1
mode: active
# Firewall
firewalls:
FIREWALL01:
rack: RackB
adapters:
- endpoint_ports: [ E0, E1 ]
switch_ports: [ Ethernet20, Ethernet20 ]
switches: [ DC1-LEAF2A, DC1-LEAF2B ]
profile: TENANT_A_B
port_channel:
description: PortChanne1
mode: active
# Routers
routers:
ROUTER01:
rack: RackB
adapters:
- endpoint_ports: [ Eth0, Eth1 ]
switch_ports: [ Ethernet21, Ethernet21 ]
switches: [ DC1-LEAF2A, DC1-LEAF2B ]
profile: TENANT_A
Single attached endpoint example¶
Single attached interface from E0
toward DC1-LEAF1A
interface Eth5
servers:
server01:
rack: RackB
adapters:
- endpoint_ports: [ E0 ]
switch_ports: [ Ethernet5 ]
switches: [ DC1-LEAF1A ]
profile: MGMT
MLAG dual-attached endpoint example¶
MLAG dual-homed connection:
- From
E0
toDC1-SVC3A
interfaceEth10
- From
E1
toDC1-SVC3B
interfaceEth10
servers:
server01:
rack: RackB
adapters:
- endpoint_ports: [ E0, E1 ]
switch_ports: [ Ethernet10, Ethernet10 ]
switches: [ DC1-SVC3A, DC1-SVC3B ]
profile: VM_Servers
port_channel:
description: PortChanne1
mode: active
EVPN A/A ESI dual-attached endpoint examples¶
To help provide consistency when configuring EVPN A/A ESI values, arista.avd provides an abstraction in the form of a short_esi
key.
short_esi
is an abbreviated 3 octets value to encode Ethernet Segment ID and LACP ID.
Transformation from abstraction to network values is managed by a filter_plugin and provides following result:
- EVPN ESI: 000:000:0303:0202:0101
- LACP ID: 0303.0202.0101
- Route Target: 03:03:02:02:01:01
In addition, setting the short_esi
key to auto
generates the short_esi automatically using a hash of the following data elements:
- Port-Channel Interfaces: first two uplink switch hostnames, the ports on those switches, the corresponding endpoint ports and the channel-group ID.
- Port-Channel Subinterface: first two uplink switch hostname, the ports on those switches, the corresponding endpoint ports, the channel-group ID and the subinterface number.
- Ethernet Interfaces: first two uplink switch hostnames, the ports on those switches, the corresponding endpoint ports and the interface number.
It should be noted that arista.avd does not currently check for hash collisions when using short_esi: auto
and while the risk of this happening is non-zero, it is small.
Active/Active multihoming connections:
- From
E0
toDC1-SVC3A
interfaceEth10
- From
E1
toDC1-SVC4A
interfaceEth10
servers:
server01:
rack: RackB
adapters:
- endpoint_ports: [ E0, E1 ]
switch_ports: [ Ethernet10, Ethernet10 ]
switches: [ DC1-SVC3A, DC1-SVC4A ]
profile: VM_Servers
port_channel:
description: PortChanne1
mode: active
short_esi: 0303:0202:0101
Example using network ports and profiles¶
# Port Profiles
# Common settings inherited to network_ports
port_profiles:
- profile: common
mode: access
vlans: "999"
spanning_tree_portfast: edge
spanning_tree_bpdufilter: enabled
- profile: ap_with_port_channel
parent_profile: common
vlans: "101"
port_channel:
mode: active
- profile: pc
parent_profile: common
vlans: "100"
# Network Ports
# All switch_ports ranges are expanded into individual port configurations
# Switches are matched with regex matching the full hostname.
network_ports:
- switches:
- network-ports-tests-1
switch_ports:
- Ethernet1-2
profile: pc
description: PCs
- switches:
- network-ports-tests-2$
switch_ports:
- Ethernet1-2
profile: ap_with_port_channel
description: AP1 with port_channel
- switches:
- network-ports-[est]{5}-.*
switch_ports:
- Ethernet3-4
- Ethernet2/1-48
profile: pc